Material: Noryl®

Polyphenylene Oxide, Modified

Noryl® due to its inherent chemical composition, exhibits unusually low moisture absorption. Therefore, good electrical insulating properties are realized over a wide range of humidity and temperature conditions. Chemical attack from water, most salt solutions, acids and bases is also minimal with Noryl®. The addition of glass fiber reinforcement enhances both th mechanical and thermal properties of the basic Noryl® material. This material also offers good electrical insulating properties along with long term dimensional stability.

Mechanical Properties Test Method ASTM Value Units




Density D792 0.0383 lbs/in3
Specific Gravity D792 1.08 g/cc
Water Absorption @ 24 hours, 73°F D570 0.07 %
Water Absorption @ Saturation, 73°F D570 0 %
Tensile Strength, 73°F D638 9,200 psi
Tensile Modulus D639 3.5 x 105 psi
Elongation ( at break), 73°F D638 25 %
Flexural Strength, 73°F D790 13,400 psi
Flexural Modulus, 73°F D790 3.7 x 105 psi
Compressive Strength D695   psi
Izod Impact Strength, 73°F D256 4 ft-lb/in of notch
Rockwell Hardness, 73°F D785 R - 119 M or R Scale
Shure Hardness     D Scale
Wear Factor Against Steel, 40 psi, 50 fpm D3702   in.3-min/ft.lbs.hr
Static Coefficient of Friction D3702    
Dynamic Coefficient of Friction, 40 pcs, 50 fpm D3702
 




Thermal Properties








Heat Deflection Temperature @ 66 psi D648 279 °F
Heat Deflection Temperature @ 264 psi D648 254 °F
Coefficient of Linear Thermal Expansion D696 3.3 X 10-5 in/in./°F
Continuous Servicing Temperature, Intermittent
230 °F
Continuous Servicing Temperature, Long Term UL746B
220 °F
Specific Heat
0.4 BTU/lb -°F
Thermal Conductivity
   
Melting Point D2133
310
°F
Flammability UL94
V-2 (3.0) (mm)


 
Electrical Properties








Surface Resistivity D257   ohm/square
Volume Resistivity D257 1 x 1017 ohm - cm
Dielectric Strength D149 500 Volts/mil
Dielectric Constant, 60 Hz, 73°F, 50% RH D150
2.7  
Dissipation Factor, 60 HZ, 73°F D150 0.0007  


   
*The values shown in these and the following charts are typical, average properties. Actual values may differ due to variations in resin formulations and processing methods. These values are obtained from sources believed to be reliable, including the resin manufactures, converters and other published sources. However, they should not be used for specification or design purposes.